Search

Search Results (399218 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2020-16244 1 Ge 1 Asset Performance Management Classic 2024-11-21 7.2 High
GE Digital APM Classic, Versions 4.4 and prior. Salt is not used for hash calculation of passwords, making it possible to decrypt passwords. This design flaw, along with the IDOR vulnerability, puts the entire platform at high risk because an authenticated user can retrieve all user account data and then retrieve the actual passwords.
CVE-2020-16243 1 We-con 1 Levistudiou 2024-11-21 7.8 High
Multiple buffer overflow vulnerabilities exist when LeviStudioU (Version 2019-09-21 and prior) processes project files. Opening a specially crafted project file could allow an attacker to exploit and execute code under the privileges of the application.
CVE-2020-16242 1 Ge 4 S2020, S2020 Firmware, S2024 and 1 more 2024-11-21 6.1 Medium
The affected Reason S20 Ethernet Switch is vulnerable to cross-site scripting (XSS), which may allow an attacker to trick application users into performing critical application actions that include, but are not limited to, adding and updating accounts.
CVE-2020-16240 1 Ge 1 Asset Performance Management Classic 2024-11-21 5.3 Medium
GE Digital APM Classic, Versions 4.4 and prior. An insecure direct object reference (IDOR) vulnerability allows user account data to be downloaded in JavaScript object notation (JSON) format by users who should not have access to such functionality. An attacker can download sensitive data related to user accounts without having the proper privileges.
CVE-2020-16236 1 Panasonic 1 Fpwin Pro 2024-11-21 7.8 High
FPWIN Pro is vulnerable to an out-of-bounds read vulnerability when a user opens a maliciously crafted project file, which may allow an attacker to remotely execute arbitrary code.
CVE-2020-16234 1 Fatek 1 Winproladder 2024-11-21 7.8 High
In PLC WinProladder Version 3.28 and prior, a stack-based buffer overflow vulnerability can be exploited when a valid user opens a specially crafted file, which may allow an attacker to remotely execute arbitrary code.
CVE-2020-16233 1 Wibu 1 Codemeter 2024-11-21 7.5 High
An attacker could send a specially crafted packet that could have CodeMeter (All versions prior to 7.10) send back packets containing data from the heap.
CVE-2020-16230 1 Hms-networks 4 Ewon Cosy, Ewon Cosy Firmware, Ewon Flexy and 1 more 2024-11-21 2.3 Low
All version of Ewon Flexy and Cosy prior to 14.1 use wildcards such as (*) under which domains can request resources. An attacker with local access and high privileges could inject scripts into the Cross-origin Resource Sharing (CORS) configuration that could abuse this vulnerability, allowing the attacker to retrieve limited confidential information through sniffing.
CVE-2020-16229 1 Advantech 1 Webaccess\/hmi Designer 2024-11-21 7.8 High
Advantech WebAccess HMI Designer, Versions 2.1.9.31 and prior. Processing specially crafted project files lacking proper validation of user supplied data may cause a type confusion condition, which may allow remote code execution, disclosure/modification of information, or cause the application to crash.
CVE-2020-16228 1 Philips 24 Intellivue Mp2-mp90, Intellivue Mp2-mp90 Firmware, Intellivue Mx100 and 21 more 2024-11-21 6.4 Medium
In Patient Information Center iX (PICiX) Versions C.02 and C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX550, MX750, MX850, and IntelliVue X3 Versions N and prior, the software does not check or incorrectly checks the revocation status of a certificate, which may cause it to use a compromised certificate.
CVE-2020-16227 1 Deltaww 1 Tpeditor 2024-11-21 7.8 High
Delta Electronics TPEditor Versions 1.97 and prior. An improper input validation may be exploited by processing a specially crafted project file not validated when the data is entered by a user. Successful exploitation of this vulnerability may allow an attacker to read/modify information, execute arbitrary code, and/or crash the application.
CVE-2020-16226 1 Mitsubishielectric 186 Conveyor Tracking Application Apr-ntr12fh, Conveyor Tracking Application Apr-ntr20fh\(n\=1\,2\), Conveyor Tracking Application Apr-ntr3fh and 183 more 2024-11-21 9.8 Critical
Multiple Mitsubishi Electric products are vulnerable to impersonations of a legitimate device by a malicious actor, which may allow an attacker to remotely execute arbitrary commands.
CVE-2020-16225 1 Deltaww 1 Tpeditor 2024-11-21 7.8 High
Delta Electronics TPEditor Versions 1.97 and prior. A write-what-where condition may be exploited by processing a specially crafted project file. Successful exploitation of this vulnerability may allow an attacker to read/modify information, execute arbitrary code, and/or crash the application.
CVE-2020-16224 1 Philips 1 Patient Information Center Ix 2024-11-21 6.5 Medium
In Patient Information Center iX (PICiX) Versions C.02, C.03, the software parses a formatted message or structure but does not handle or incorrectly handles a length field that is inconsistent with the actual length of the associated data, causing the application on the surveillance station to restart.
CVE-2020-16223 1 Deltaww 1 Tpeditor 2024-11-21 7.8 High
Delta Electronics TPEditor Versions 1.97 and prior. A heap-based buffer overflow may be exploited by processing a specially crafted project file. Successful exploitation of this vulnerability may allow an attacker to read/modify information, execute arbitrary code, and/or crash the application.
CVE-2020-16222 1 Philips 2 Patient Information Center Ix, Performancebridge Focal Point 2024-11-21 8.8 High
In Patient Information Center iX (PICiX) Version B.02, C.02, C.03, and PerformanceBridge Focal Point Version A.01, when an actor claims to have a given identity, the software does not prove or insufficiently proves the claim is correct.
CVE-2020-16221 1 Deltaww 1 Tpeditor 2024-11-21 7.8 High
Delta Electronics TPEditor Versions 1.97 and prior. A stack-based buffer overflow may be exploited by processing a specially crafted project file. Successful exploitation of this vulnerability may allow an attacker to read/modify information, execute arbitrary code, and/or crash the application.
CVE-2020-16220 1 Philips 2 Patient Information Center Ix, Performancebridge Focal Point 2024-11-21 4.3 Medium
In Patient Information Center iX (PICiX) Versions C.02, C.03, PerformanceBridge Focal Point Version A.01, the product receives input that is expected to be well-formed (i.e., to comply with a certain syntax) but it does not validate or incorrectly validates that the input complies with the syntax, causing the certificate enrollment service to crash. It does not impact monitoring but prevents new devices from enrolling.
CVE-2020-16219 1 Deltaww 1 Tpeditor 2024-11-21 7.8 High
Delta Electronics TPEditor Versions 1.97 and prior. An out-of-bounds read may be exploited by processing specially crafted project files. Successful exploitation of this vulnerability may allow an attacker to read/modify information, execute arbitrary code, and/or crash the application.
CVE-2020-16218 1 Philips 1 Patient Information Center Ix 2024-11-21 3.5 Low
In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is then used as a webpage and served to other users. Successful exploitation could lead to unauthorized access to patient data via a read-only web application.