| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A vulnerability, which was classified as problematic, was found in Done-0 Jank up to 322caebbad10568460364b9667aa62c3080bfc17. Affected is an unknown function of the file internal/utils/jwt_utils.go of the component JWT Token Handler. The manipulation of the argument accessSecret/refreshSecret with the input jank-blog-secret/jank-blog-refresh-secret leads to use of hard-coded password. It is possible to launch the attack remotely. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. Continious delivery with rolling releases is used by this product. Therefore, no version details of affected nor updated releases are available. |
| The Carlo Gavazzi
EOS-Box
stores hard-coded passwords in the PHP file of
the device. By using the hard-coded passwords, attackers can log into
the device with administrative privileges. This could allow the attacker
to have unauthorized access. |
| WellinTech KingSCADA 3.0 uses a cleartext base64 format for storage of passwords in user.db, which allows context-dependent attackers to obtain sensitive information by reading this file. |
| The potential exists for exposure of the product's password used to restrict unauthorized access to Rockwell PLC5/SLC5/0x/RSLogix 1785-Lx and 1747-L5x controllers. The potential exists for an unauthorized programming and configuration client to gain access to the product and allow changes to the product’s configuration or program. When applicable, upgrade product firmware to a version that includes enhanced security functionality compatible with Rockwell Automation's FactoryTalk Security services. |
| A vulnerability, which was classified as problematic, has been found in TOTOLINK T10 4.1.8cu.5207. Affected by this issue is some unknown functionality of the file /etc/shadow.sample. The manipulation leads to use of hard-coded password. The attack can only be initiated within the local network. The complexity of an attack is rather high. The exploitation is known to be difficult. The exploit has been disclosed to the public and may be used. |
| The PAM module for fscrypt doesn't adequately validate fscrypt metadata files, allowing users to create malicious metadata files that prevent other users from logging in. A local user can cause a denial of service by creating a fscrypt metadata file that prevents other users from logging into the system. We recommend upgrading to version 0.3.3 or above |
| Multiple directory traversal vulnerabilities in Polycom RealPresence Resource Manager (aka RPRM) before 8.4 allow (1) remote authenticated users to read arbitrary files via a .. (dot dot) in the Modifier parameter to PlcmRmWeb/FileDownload; or remote authenticated administrators to upload arbitrary files via the (2) Filename or (3) SE_FNAME parameter to PlcmRmWeb/FileUpload or to read and remove arbitrary files via the (4) filePathName parameter in an importSipUriReservations SOAP request to PlcmRmWeb/JUserManager. |
| The Embedded Jopr component in JBoss Application Server includes the cleartext datasource password in unspecified HTML responses, which might allow (1) man-in-the-middle attackers to obtain sensitive information by leveraging failure to use SSL or (2) attackers to obtain sensitive information by reading the HTML source code. NOTE: the vendor says that this does not cross a trust boundary and that it is recommended best-practice that SSL is configured for the administrative console |
| MultiTech FaxFinder before 4.1.2 stores Passwords unencrypted for maintaining the test connectivity function of its LDAP configuration. These credentials are retrieved by the system when the LDAP configuration page is opened and are embedded directly into the HTML source code in cleartext. |
| A vulnerability in Cisco Aironet 1830 Series and Cisco Aironet 1850 Series Access Points running Cisco Mobility Express Software could allow an unauthenticated, remote attacker to take complete control of an affected device. The vulnerability is due to the existence of default credentials for an affected device that is running Cisco Mobility Express Software, regardless of whether the device is configured as a master, subordinate, or standalone access point. An attacker who has layer 3 connectivity to an affected device could use Secure Shell (SSH) to log in to the device with elevated privileges. A successful exploit could allow the attacker to take complete control of the device. This vulnerability affects Cisco Aironet 1830 Series and Cisco Aironet 1850 Series Access Points that are running an 8.2.x release of Cisco Mobility Express Software prior to Release 8.2.111.0, regardless of whether the device is configured as a master, subordinate, or standalone access point. Release 8.2 was the first release of Cisco Mobility Express Software for next generation Cisco Aironet Access Points. Cisco Bug IDs: CSCva50691. |
| An issue was discovered in Siemens SICAM PAS before 8.00. Because of Storing Passwords in a Recoverable Format, an authenticated local attacker with certain privileges could possibly reconstruct the passwords of users for accessing the database. |
| An issue was discovered in Becton, Dickinson and Company (BD) Alaris 8015 Point of Care (PC) unit, Version 9.5 and prior versions, and Version 9.7. An unauthorized user with physical access to an Alaris 8015 PC unit may be able to obtain unencrypted wireless network authentication credentials and other sensitive technical data by disassembling an Alaris 8015 PC unit and accessing the device's flash memory. Older software versions of the Alaris 8015 PC unit, Version 9.5 and prior versions, store wireless network authentication credentials and other sensitive technical data on the affected device's removable flash memory. Being able to remove the flash memory from the affected device reduces the risk of detection, allowing an attacker to extract stored data at the attacker's convenience. |
| A remote unauthenticated network based attacker with access to Junos Space may execute arbitrary code on Junos Space or gain access to devices managed by Junos Space using cross site request forgery (CSRF), default authentication credentials, information leak and command injection attack vectors. All versions of Juniper Networks Junos Space prior to 15.1R3 are affected. |
| Wi-Fi STATION L-02F Software version V10g and earlier allows remote attackers to access the device with administrative privileges and perform unintended operations through a backdoor account. |
| Polycom RealPresence Resource Manager (aka RPRM) before 8.4 allows local users to have unspecified impact via vectors related to weak passwords. |
| SeaWell Networks Spectrum SDC 02.05.00 has a default password of "admin" for the "admin" account. |
| IBM Kenexa LCMS Premier on Cloud stores user credentials in plain in clear text which can be read by an authenticated user. |
| An issue was discovered in Moxa NPort 5110 versions prior to 2.6, NPort 5130/5150 Series versions prior to 3.6, NPort 5200 Series versions prior to 2.8, NPort 5400 Series versions prior to 3.11, NPort 5600 Series versions prior to 3.7, NPort 5100A Series & NPort P5150A versions prior to 1.3, NPort 5200A Series versions prior to 1.3, NPort 5150AI-M12 Series versions prior to 1.2, NPort 5250AI-M12 Series versions prior to 1.2, NPort 5450AI-M12 Series versions prior to 1.2, NPort 5600-8-DT Series versions prior to 2.4, NPort 5600-8-DTL Series versions prior to 2.4, NPort 6x50 Series versions prior to 1.13.11, NPort IA5450A versions prior to v1.4. A configuration file contains parameters that represent passwords in plaintext. |
| /var/lib/ovirt-engine/setup/engine-DC-config.py in Red Hat QuickStart Cloud Installer (QCI) before 1.0 GA is created world readable and contains the root password of the deployed system. |
| An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E1212, firmware Version V2.4 and prior, ioLogik E1213, firmware Version V2.5 and prior, ioLogik E1214, firmware Version V2.4 and prior, ioLogik E1240, firmware Version V2.3 and prior, ioLogik E1241, firmware Version V2.4 and prior, ioLogik E1242, firmware Version V2.4 and prior, ioLogik E1260, firmware Version V2.4 and prior, ioLogik E1262, firmware Version V2.4 and prior, ioLogik E2210, firmware versions prior to V3.13, ioLogik E2212, firmware versions prior to V3.14, ioLogik E2214, firmware versions prior to V3.12, ioLogik E2240, firmware versions prior to V3.12, ioLogik E2242, firmware versions prior to V3.12, ioLogik E2260, firmware versions prior to V3.13, and ioLogik E2262, firmware versions prior to V3.12. A password is transmitted in a format that is not sufficiently secure. |