Search Results (44955 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-53007 2026-04-15 N/A
arduino-esp32 provides an Arduino core for the ESP32. Versions prior to 3.3.0-RC1 and 3.2.1 contain a HTTP Response Splitting vulnerability. The `sendHeader` function takes arbitrary input for the HTTP header name and value, concatenates them into an HTTP header line, and appends this to the outgoing HTTP response headers. There is no validation or sanitization of the `name` or `value` parameters before they are included in the HTTP response. If an attacker can control the input to `sendHeader` (either directly or indirectly), they could inject carriage return (`\r`) or line feed (`\n`) characters into either the header name or value. This could allow the attacker to inject additional headers, manipulate the structure of the HTTP response, potentially inject an entire new HTTP response (HTTP Response Splitting), and/or ause header confusion or other HTTP protocol attacks. Versions 3.3.0-RC1 and 3.2.1 contain a fix for the issue.
CVE-2025-4657 2026-04-15 6.7 Medium
A buffer overflow vulnerability was reported in the Lenovo Protection Driver, prior to version 5.1.1110.4231, used in Lenovo PC Manager, Lenovo Browser, and Lenovo App Store could allow a local attacker with elevated privileges to execute arbitrary code.
CVE-2025-41726 1 Beckhoff 4 Beckhoff.device.manager.xar, Mdp Package, Twincat and 1 more 2026-04-15 8.8 High
A low privileged remote attacker can execute arbitrary code by sending specially crafted calls to the web service of the Device Manager or locally via an API and can cause integer overflows which then may lead to arbitrary code execution within privileged processes.
CVE-2025-3854 2026-04-15 8 High
A vulnerability, which was classified as critical, was found in H3C GR-3000AX up to V100R006. Affected is the function EnableIpv6/UpdateWanModeMulti/UpdateIpv6Params/EditWlanMacList/Edit_List_SSID of the file /goform/aspForm of the component HTTP POST Request Handler. The manipulation of the argument param leads to buffer overflow. The attack needs to be initiated within the local network. The exploit has been disclosed to the public and may be used. It is recommended to upgrade the affected component. Other functions might be affected as well.
CVE-2025-24376 2026-04-15 6.5 Medium
kubewarden-controller is a Kubernetes controller that allows you to dynamically register Kubewarden admission policies. By design, AdmissionPolicy and AdmissionPolicyGroup can evaluate only namespaced resources. The resources to be evaluated are determined by the rules provided by the user when defining the policy. There might be Kubernetes namespaced resources that should not be validated by AdmissionPolicy and by the AdmissionPolicyGroup policies because of their sensitive nature. For example, PolicyReport are namespaced resources that contain the list of non compliant objects found inside of a namespace. An attacker can use either an AdmissionPolicy or an AdmissionPolicyGroup to prevent the creation and update of PolicyReport objects to hide non-compliant resources. Moreover, the same attacker might use a mutating AdmissionPolicy to alter the contents of the PolicyReport created inside of the namespace. Starting from the 1.21.0 release, the validation rules applied to AdmissionPolicy and AdmissionPolicyGroup have been tightened to prevent them from validating sensitive types of namespaced resources.
CVE-2025-24359 2026-04-15 8.4 High
ASTEVAL is an evaluator of Python expressions and statements. Prior to version 1.0.6, if an attacker can control the input to the `asteval` library, they can bypass asteval's restrictions and execute arbitrary Python code in the context of the application using the library. The vulnerability is rooted in how `asteval` performs handling of `FormattedValue` AST nodes. In particular, the `on_formattedvalue` value uses the dangerous format method of the str class. The code allows an attacker to manipulate the value of the string used in the dangerous call `fmt.format(__fstring__=val)`. This vulnerability can be exploited to access protected attributes by intentionally triggering an `AttributeError` exception. The attacker can then catch the exception and use its `obj` attribute to gain arbitrary access to sensitive or protected object properties. Version 1.0.6 fixes this issue.
CVE-2025-24338 2026-04-15 7.1 High
A vulnerability in the “Manages app data” functionality of the web application of ctrlX OS allows a remote authenticated (lowprivileged) attacker to execute arbitrary client-side code in the context of another user's browser via multiple crafted HTTP requests.
CVE-2025-5124 2026-04-15 8.1 High
A vulnerability classified as critical has been found in Sony SNC-M1, SNC-M3, SNC-RZ25N, SNC-RZ30N, SNC-DS10, SNC-CS3N and SNC-RX570N up to 1.30. This affects an unknown part of the component Administrative Interface. The manipulation leads to use of default credentials. It is possible to initiate the attack remotely. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. It is recommended to change the configuration settings. The vendor was contacted early about this issue. They confirmed the existence but pointed out that they "have published the 'Hardening Guide' on the Web from July 2018 to January 2025 and have thoroughly informed customers of the recommendation to change their initial passwords".
CVE-2024-53426 1 Ntop 1 Ntopng 2026-04-15 6.2 Medium
A heap-buffer-overflow vulnerability has been identified in ntopng 6.2 in the Flow::dissectMDNS function.
CVE-2025-65922 1 Planka 1 Planka 2026-04-15 4.3 Medium
PLANKA 2.0.0 lacks X-Frame-Options and CSP frame-ancestors headers, allowing the application to be embedded within malicious iframes. While this does not lead to unintended modification of projects or tasks, it exposes users to Phishing attacks. Attackers can frame the legitimate Planka application on a malicious site to establish false trust (UI Redressing), potentially tricking users into entering sensitive information or credentials into overlaid fake forms. NOTE: this is disputed by the Supplier because "PLANKA uses SameSite=Strict cookies, preventing authentication in cross-origin contexts. No session can be established. No credential interception or unauthorized actions are possible. Browser Same-Origin Policy prevents the parent page from accessing iframe content. Clickjacking is not applicable on the login page. Any credential capture would require attacker-controlled input and user interaction equivalent to phishing. The security outcome depends entirely on the user's trust in the parent page. An attacker can achieve the same effect with a fully fake login page. Embedding the legitimate page adds no risk, as browsers do not show URL, certificate, or padlock indicators in cross-origin iframes."
CVE-2025-57351 2026-04-15 6.5 Medium
A prototype pollution vulnerability exists in the ts-fns package versions prior to 13.0.7, where insufficient validation of user-provided keys in the assign function allows attackers to manipulate the Object.prototype chain. By leveraging this flaw, adversaries may inject arbitrary properties into the global object's prototype, potentially leading to application crashes, unexpected code execution behaviors, or bypasses of security-critical validation logic dependent on prototype integrity. The vulnerability stems from improper handling of deep property assignment operations within the library's public API functions. This issue remains unaddressed in the latest available version.
CVE-2025-57352 2026-04-15 5.3 Medium
A vulnerability exists in the 'min-document' package prior to version 2.19.0, stemming from improper handling of namespace operations in the removeAttributeNS method. By processing malicious input involving the __proto__ property, an attacker can manipulate the prototype chain of JavaScript objects, leading to denial of service or arbitrary code execution. This issue arises from insufficient validation of attribute namespace removal operations, allowing unintended modification of critical object prototypes. The vulnerability remains unaddressed in the latest available version.
CVE-2025-50572 2026-04-15 8.8 High
Archer 6.11.00204.10014 allows attackers to execute arbitrary code via crafted system inputs that would be exported into the CSV and be executed after the user opened the file with compatible applications. NOTE: the Supplier does not accept this as a valid vulnerability report against their product.
CVE-2024-49775 2026-04-15 9.8 Critical
A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2501.0001), Opcenter Intelligence (All versions < V2501.0001), Opcenter Quality (All versions < V2512), Opcenter RDnL (All versions < V2410), SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions < V4.1 Update 3), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1), SINEC NMS (All versions if operated in conjunction with UMC < V2.15), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions). Affected products contain a heap-based buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to execute arbitrary code.
CVE-2025-59097 1 Dormakaba 1 Access Manager 2026-04-15 N/A
The exos 9300 application can be used to configure Access Managers (e.g. 92xx, 9230 and 9290). The configuration is done in a graphical user interface on the dormakaba exos server. As soon as the save button is clicked in exos 9300, the whole configuration is sent to the selected Access Manager via SOAP. The SOAP request is sent without any prior authentication or authorization by default. Though authentication and authorization can be configured using IPsec for 92xx-K5 devices and mTLS for 92xx-K7 devices, it is not enabled by default and must therefore be activated with additional steps. This insecure default allows an attacker with network level access to completely control the whole environment. An attacker is for example easily able to conduct the following tasks without prior authentication: - Re-configure Access Managers (e.g. remove alarming system requirements) - Freely re-configure the inputs and outputs - Open all connected doors permanently - Open all doors for a defined time interval - Change the admin password - and many more Network level access can be gained due to an insufficient network segmentation as well as missing LAN firewalls. Devices with an insecure configuration have been identified to be directly exposed to the internet.
CVE-2025-59103 1 Dormakaba 1 Access Manager 2026-04-15 N/A
The Access Manager 92xx in hardware revision K7 is based on Linux instead of Windows CE embedded in older hardware revisions. In this new hardware revision it was noticed that an SSH service is exposed on port 22. By analyzing the firmware of the devices, it was noticed that there are two users with hardcoded and weak passwords that can be used to access the devices via SSH. The passwords can be also guessed very easily. The password of at least one user is set to a random value after the first deployment, with the restriction that the password is only randomized if the configured date is prior to 2022. Therefore, under certain circumstances, the passwords are not randomized. For example, if the clock is never set on the device, the battery of the clock module has been changed, the Access Manager has been factory reset and has not received a time yet.
CVE-2025-59109 1 Dormakaba 1 Registration Unit 9002 2026-04-15 N/A
The dormakaba registration units 9002 (PIN Pad Units) have an exposed UART header on the backside. The PIN pad is sending every button press to the UART interface. An attacker can use the interface to exfiltrate PINs. As the devices are explicitly built as Plug-and-Play to be easily replaced, an attacker is easily able to remove the device, install a hardware implant which connects to the UART and exfiltrates the data exposed via UART to another system (e.g. via WiFi).
CVE-2025-6603 2026-04-15 5.3 Medium
A vulnerability was found in coldfunction qCUDA up to db0085400c2f2011eed46fbc04fdc0873141688e. It has been rated as problematic. Affected by this issue is the function qcow_make_empty of the file qCUDA/qcu-device/block/qcow.c. The manipulation of the argument s->l1_size leads to integer overflow. The attack needs to be approached locally. This product is using a rolling release to provide continious delivery. Therefore, no version details for affected nor updated releases are available.
CVE-2025-5257 1 Mautic 1 Mautic 2026-04-15 6.5 Medium
SummaryThis advisory addresses a security vulnerability in Mautic where unpublished page previews could be accessed by unauthenticated users and potentially indexed by search engines. This could lead to the unintended disclosure of draft content or sensitive information. Unauthorized Access to Unpublished Page Previews: The page preview functionality for unpublished content, accessible via predictable URLs (e.g., /page/preview/1, /page/preview/2), lacked proper authorization checks. This allowed any unauthenticated user to view content that was not yet intended for public release, and allowed search engines to index these private preview URLs, making the content publicly discoverable. MitigationMautic has patched this vulnerability by enforcing proper permission checks on preview pages. Users should upgrade to the patched version of Mautic or later.
CVE-2025-14911 1 Mongodb 1 C Driver 2026-04-15 6.5 Medium
User-controlled chunkSize metadata from MongoDB lacks appropriate validation allowing malformed GridFS metadata to overflow the bounding container.