| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The affected product uses a hard-coded blowfish key for encryption/decryption processes. The key can be easily extracted from binaries. |
| A path traversal vulnerability in the Moxa MXview Network Management software Versions 3.x to 3.2.2 may allow an attacker to create or overwrite critical files used to execute code, such as programs or libraries. |
| The data of a network capture of the initial handshake phase can be used to authenticate at a SYSDBA level. If a specific .exe is not restarted often, it is possible to access the needed handshake packets between admin/client connections. Using the SYSDBA permission, an attacker can change user passwords or delete the database. |
| The affected product’s OS Service does not verify any given parameter. A user can supply any type of parameter that will be passed to inner calls without checking the type of the parameter or the value. |
| A path traversal vulnerability in the Moxa MXview Network Management software Versions 3.x to 3.2.2 may allow an attacker to create or overwrite critical files used to execute code, such as programs or libraries. |
| The affected controllers do not properly sanitize the input containing code syntax. As a result, an attacker could craft code to alter the intended controller flow of the software. |
| FATEK Automation WinProladder versions 3.30 and prior lacks proper validation of user-supplied data when parsing project files, which could result in a heap-corruption condition. An attacker could leverage this vulnerability to execute code in the context of the current process. |
| A use after free vulnerability in FATEK Automation WinProladder versions 3.30 and prior may be exploited when a valid user opens a malformed project file, which may allow arbitrary code execution. |
| FATEK Automation WinProladder versions 3.30 and prior lacks proper validation of user-supplied data when parsing project files, which could result in a memory-corruption condition. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process. |
| FATEK Automation WinProladder versions 3.30 and prior lacks proper validation of user-supplied data when parsing project files, which could result in an unexpected sign extension. An attacker could leverage this vulnerability to execute arbitrary code. |
| FATEK Automation WinProladder versions 3.30 and prior proper validation of user-supplied data when parsing project files, which could result in a stack-based buffer overflow. An attacker could leverage this vulnerability to execute arbitrary code. |
| FATEK Automation WinProladder versions 3.30 and prior lacks proper validation of user-supplied data when parsing project files, which could result in an out-of-bounds write. An attacker could leverage this vulnerability to execute arbitrary code. |
| Delta Electronics DIALink versions 1.2.4.0 and prior stores sensitive information in cleartext, which may allow an attacker to have extensive access to the application directory and escalate privileges. |
| Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an out-of-bounds read, which may allow an attacker to read sensitive information from other memory locations or cause a crash. |
| Delta Electronics DIALink versions 1.2.4.0 and prior default permissions give extensive permissions to low-privileged user accounts, which may allow an attacker to modify the installation directory and upload malicious files. |
| Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an out-of-bounds write, which can result in data corruption, a system crash, or code execution. |
| Delta Electronics DIALink versions 1.2.4.0 and prior runs by default on HTTP, which may allow an attacker to be positioned between the traffic and perform a machine-in-the-middle attack to access information without authorization. |
| Delta Electronics DIALink versions 1.2.4.0 and prior insecurely loads libraries, which may allow an attacker to use DLL hijacking and takeover the system where the software is installed. |
| Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable a heap-based buffer overflow when parsing a specially crafted project file, which may allow an attacker to execute arbitrary code. |
| Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to a stack-based buffer overflow, which may allow an attacker to achieve code execution. |