| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Dell ECS, versions 3.8.1.0 through 3.8.1.7, and Dell ObjectScale versions prior to 4.2.0.0, contains an Use of Default Credentials vulnerability in the OS. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges. |
| A vulnerability was found in Edimax BR-6208AC 2_1.02. The affected element is the function auth_check_userpass2. Performing a manipulation of the argument Username/Password results in use of default credentials. The attack may be initiated remotely. The exploit has been made public and could be used. The vendor confirms that the affected product is end-of-life. They confirm that they "will issue a consolidated Security Advisory on our official support website." This vulnerability only affects products that are no longer supported by the maintainer. |
| eNet SMART HOME server 2.2.1 and 2.3.1 ships with default credentials (user:user, admin:admin) that remain active after installation and commissioning without enforcing a mandatory password change. Unauthenticated attackers can use these default credentials to gain administrative access to sensitive smart home configuration and control functions. |
| Default credentials set for local privileged user in Virtual Appliance. The following products are affected: Acronis Cyber Protect Cloud Agent (VMware) before build 36943, Acronis Cyber Protect 17 (VMware) before build 41186. |
| Tattile Smart+, Vega, and Basic device families firmware versions 1.181.5 and prior ship with default credentials that are not forced to be changed during installation or commissioning. An attacker who can reach the management interface can authenticate using the default credentials and gain administrative access, enabling unauthorized access to device configuration and data. |
| SODOLA SL902-SWTGW124AS firmware versions through 200.1.20 contain a default credentials vulnerability that allows remote attackers to obtain administrative access to the management interface. Attackers can authenticate using the hardcoded default credentials without password change enforcement to gain full administrative control of the device. |
| OpenMQ exposes a TCP-based management service (imqbrokerd) that by default requires
authentication. However, the product ships with a default administrative account (admin/
admin) and does not enforce a mandatory password change on first use. After the first
successful login, the server continues to accept the default password indefinitely without
warning or enforcement.
In real-world deployments, this service is often left enabled without changing the default
credentials. As a result, a remote attacker with access to the service port could authenticate
as an administrator and gain full control of the protocol’s administrative features. |
| Istio is an open platform to connect, manage, and secure microservices. Prior to 1.29.1, 1.28.5, and 1.27.8, a user of Istio is impacted if the JWKS resolver becomes unavailable or the fetch fails, exposing hardcoded defaults regardless of use of the RequestAuthentication resource. This vulnerability is fixed in 1.29.1, 1.28.5, and 1.27.8. |
| A CWE-1392 “Use of Default Credentials” was discovered affecting the 130.8005 TCP/IP Gateway running firmware version 12h. The device exposes an FTP server with default and easy-to-guess admin credentials. A remote attacker capable of interacting with the FTP server could gain access and perform changes over resources exposed by the service such as configuration files where password hashes are saved or where network settings are stored. |
| MOBATIME Network Master Clock - DTS 4801 allows attackers to use SSH to gain initial access using default credentials. |
| A vulnerability classified as critical has been found in Sony SNC-M1, SNC-M3, SNC-RZ25N, SNC-RZ30N, SNC-DS10, SNC-CS3N and SNC-RX570N up to 1.30. This affects an unknown part of the component Administrative Interface. The manipulation leads to use of default credentials. It is possible to initiate the attack remotely. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. It is recommended to change the configuration settings. The vendor was contacted early about this issue. They confirmed the existence but pointed out that they "have published the 'Hardening Guide' on the Web from July 2018 to January 2025 and have thoroughly informed customers of the recommendation to change their initial passwords". |
| CWE-1392: Use of Default Credentials |
| Smartwares cameras CIP-37210AT and C724IP, as well as others which share the same firmware in versions up to 3.3.0, might share same credentials for telnet service. Hash of the password can be retrieved through physical access to SPI connected memory.
For the telnet service to be enabled, the inserted SD card needs to have a folder with a specific name created.
Two products were tested, but since the vendor has not replied to reports, patching status remains unknown, as well as groups of devices and firmware ranges in which the same password is shared.
Newer firmware versions might be vulnerable as well. |
| BrightSign players running BrightSign OS series 4 prior to v8.5.53.1 or
series 5 prior to v9.0.166 use a default password that is guessable with
knowledge of the device information. The latest release fixes this
issue for new installations; users of old installations are encouraged
to change all default passwords. |
| iMonitor EAM 9.6394 ships with default administrative credentials that are also displayed within the management client’s connection dialog. If the administrator does not change these defaults, a remote attacker can authenticate to the EAM server and gain full control over monitored agents and data. This enables reading highly sensitive telemetry (including keylogger output) and issuing arbitrary actions to all connected clients. |
| A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.90), SIPROTEC 5 6MD85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD89 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD89 (CP300) V9.6x (All versions < V9.68), SIPROTEC 5 6MU85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7KE85 (CP300) (All versions >= V8.80 < V10.0), SIPROTEC 5 7SA82 (CP150) (All versions < V9.90), SIPROTEC 5 7SA86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SA87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.90), SIPROTEC 5 7SD86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SD87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SJ86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SK82 (CP150) (All versions < V9.90), SIPROTEC 5 7SK85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.90), SIPROTEC 5 7SL86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SL87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SS85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7ST85 (CP300) (All versions >= V8.80 < V10.0), SIPROTEC 5 7ST85 (CP300) V9.6x (All versions < V9.68), SIPROTEC 5 7ST86 (CP300) (All versions < V10.0), SIPROTEC 5 7ST86 (CP300) V9.8x (All versions < V9.83), SIPROTEC 5 7SX82 (CP150) (All versions < V9.90), SIPROTEC 5 7SX85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SY82 (CP150) (All versions < V9.90), SIPROTEC 5 7UM85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.90), SIPROTEC 5 7UT85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VE85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VK87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VU85 (CP300) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.8 (All versions < V9.83), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.8 (All versions < V9.83), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions >= V8.80 < V9.90), SIPROTEC 5 Communication Module ETH-BD-2FO V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BD-2FO V9.8 (All versions < V9.83), SIPROTEC 5 Compact 7SX800 (CP050) (All versions >= V9.50 < V9.90). Affected devices do not properly validate SNMP GET requests. This could allow an unauthenticated, remote attacker to retrieve sensitive information of the affected devices with SNMPv2 GET requests using default credentials. |
| A vulnerability classified as problematic was found in SAFECAM X300 up to 20250611. This vulnerability affects unknown code of the component FTP Service. The manipulation leads to use of default credentials. Access to the local network is required for this attack to succeed. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| ANCHOR from Global Wisdom Software is an integrated product running on a Windows virtual machine. The underlying Windows OS of the product contains high-privilege service accounts. If these accounts use default passwords, attackers could remotely log in to the virtual machine using the default credentials. |
| The TELNET service of AdTran NetVanta 3120 18.01.01.00.E devices is enabled by default, and has default credentials for a root-level account. |
| Control-M/Agents use a kdb or PKCS#12 keystore by default, and the default keystore password is well known and documented.
An attacker with read access to the keystore could access sensitive data using this password. |