Search Results (36 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2017-20234 2 Belden, Garrettcom 2 Garrettcom Magnum 6k And 10k Managed Switches, Magnum Managed Networks Software-6k 2026-10-01 9.8 Critical
GarrettCom Magnum 6K and 10K managed switches contain an authentication bypass vulnerability that allows unauthenticated attackers to gain unauthorized access by exploiting a hardcoded string in the authentication mechanism. Attackers can bypass login controls to access administrative functions and sensitive switch configuration without valid credentials.
CVE-2026-89025 1 Belden 2 Hirschmann Hios, Hirschmann Hios Switch Platform 2026-10-01 7.5 High
Hirschmann HiOS Switch Platform devices contain a denial-of-service vulnerability in the integrated web server due to missing validation of HTTP(S) content. A remote unauthenticated attacker can send a specially crafted HTTP(S) request to a specific endpoint that is processed incorrectly, causing the device to perform an unintended reboot and resulting in a temporary denial-of-service condition. This vulnerability has been addressed in versions 07.1.12, 08.7.10, 09.0.13, 09.3.03, 10.3.08, and 10.5.00.
CVE-2023-7342 1 Belden 1 Hirschmann Hisecos 2026-10-01 8.8 High
HiSecOS web server versions 03.4.00 prior to 04.1.00 contains a privilege escalation vulnerability that allows authenticated users with operator or auditor roles to escalate privileges to the administrator role by sending specially crafted packets to the web server. Attackers can exploit this flaw to gain full administrative access to the affected device.
CVE-2023-53908 1 Belden 2 Hirschmann Hisecos, Hisecos 2026-10-01 8.8 High
HiSecOS 04.0.01 contains a privilege escalation vulnerability that allows authenticated users to modify their access role through XML-based NETCONF configuration. Attackers can send crafted XML payloads to the /mops_data endpoint with a specific role value to elevate their user privileges to administrative level.
CVE-2018-25237 1 Belden 2 Hirschmann Eagle One, Hirschmann Hisecos 2026-10-01 9.8 Critical
Hirschmann HiSecOS devices versions prior to 05.3.03 contain a buffer overflow vulnerability in the HTTPS login interface when RADIUS authentication is enabled that allows remote attackers to crash the device or execute arbitrary code by submitting a password longer than 128 characters. Attackers can exploit improper bounds checking in password handling to overflow a fixed-size buffer and achieve denial of service or remote code execution.
CVE-2025-70545 1 Belden 3 Ont 2k05x Router, Ppc 2k05x, Ppc 2k05x Firmware 2026-02-11 6.1 Medium
A stored cross-site scripting (XSS) vulnerability exists in the web management interface of the PPC (Belden) ONT 2K05X router running firmware v1.1.9_206L. The Common Gateway Interface (CGI) component improperly handles user-supplied input, allowing a remote, unauthenticated attacker to inject arbitrary JavaScript that is persistently stored and executed when the affected interface is accessed.
CVE-2022-40282 1 Belden 2 Hirschmann Bat-c2, Hirschmann Bat-c2 Firmware 2025-04-29 8.8 High
The web server of Hirschmann BAT-C2 before 09.13.01.00R04 allows authenticated command injection. This allows an authenticated attacker to pass commands to the shell of the system because the dir parameter of the FsCreateDir Ajax function is not sufficiently sanitized. The vendor's ID is BSECV-2022-21.
CVE-2017-11400 1 Belden 2 Tofino Xenon Security Appliance, Tofino Xenon Security Appliance Firmware 2025-04-20 N/A
An issue has been discovered on the Belden Hirschmann Tofino Xenon Security Appliance before 03.2.00. An incomplete firmware signature allows a local attacker to upgrade the equipment (kernel, file system) with unsigned, attacker-controlled, data. This occurs because the appliance_config file is signed but the .tar.sec file is unsigned.
CVE-2017-11402 1 Belden 2 Tofino Xenon Security Appliance, Tofino Xenon Security Appliance Firmware 2025-04-20 N/A
An issue has been discovered on the Belden Hirschmann Tofino Xenon Security Appliance before 03.2.00. Design flaws in OPC classic and in custom netfilter modules allow an attacker to remotely activate rules on the firewall and to connect to any TCP port of a protected asset, thus bypassing the firewall. The attack methodology is a crafted OPC dynamic port shift.
CVE-2017-11401 1 Belden 2 Tofino Xenon Security Appliance, Tofino Xenon Security Appliance Firmware 2025-04-20 N/A
An issue has been discovered on the Belden Hirschmann Tofino Xenon Security Appliance before 03.2.00. Improper handling of the mbap.length field of ModBus packets in the ModBus DPI filter allows an attacker to send malformed/crafted packets to a protected asset, bypassing function code filtering.
CVE-2016-2509 1 Belden 6 Hirschmann Firmware, Hirschmann L2b, Hirschmann L2e and 3 more 2025-04-12 N/A
The password-sync feature on Belden Hirschmann Classic Platform switches L2B before 05.3.07 and L2E, L2P, L3E, and L3P before 09.0.06 sets an SNMP community to the same string as the administrator password, which allows remote attackers to obtain sensitive information by sniffing the network.
CVE-2021-30066 2 Belden, Schneider-electric 26 Eagle 20 Tofino 943 987-501-tx\/tx, Eagle 20 Tofino 943 987-501-tx\/tx Firmware, Eagle 20 Tofino 943 987-502 -tx\/mm and 23 more 2024-11-21 6.8 Medium
On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an arbitrary firmware image can be loaded because firmware signature verification (for a USB stick) can be bypassed. NOTE: this issue exists because of an incomplete fix of CVE-2017-11400.
CVE-2021-30065 2 Belden, Schneider-electric 26 Eagle 20 Tofino 943 987-501-tx\/tx, Eagle 20 Tofino 943 987-501-tx\/tx Firmware, Eagle 20 Tofino 943 987-502 -tx\/mm and 23 more 2024-11-21 7.5 High
On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, crafted ModBus packets can bypass the ModBus enforcer. NOTE: this issue exists because of an incomplete fix of CVE-2017-11401.
CVE-2021-30064 2 Belden, Schneider-electric 26 Eagle 20 Tofino 943 987-501-tx\/tx, Eagle 20 Tofino 943 987-501-tx\/tx Firmware, Eagle 20 Tofino 943 987-502 -tx\/mm and 23 more 2024-11-21 9.8 Critical
On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an SSH login can succeed with hardcoded default credentials (if the device is in the uncommissioned state).
CVE-2021-30063 2 Belden, Schneider-electric 22 Eagle 20 Tofino 943 987-501-tx\/tx, Eagle 20 Tofino 943 987-501-tx\/tx Firmware, Eagle 20 Tofino 943 987-502 -tx\/mm and 19 more 2024-11-21 7.5 High
On Schneider Electric ConneXium Tofino OPCLSM TCSEFM0000 before 03.23 and Belden Tofino Xenon Security Appliance, crafted OPC packets can cause an OPC enforcer denial of service.
CVE-2021-30062 2 Belden, Schneider-electric 22 Eagle 20 Tofino 943 987-501-tx\/tx, Eagle 20 Tofino 943 987-501-tx\/tx Firmware, Eagle 20 Tofino 943 987-502 -tx\/mm and 19 more 2024-11-21 7.5 High
On Schneider Electric ConneXium Tofino OPCLSM TCSEFM0000 before 03.23 and Belden Tofino Xenon Security Appliance, crafted OPC packets can bypass the OPC enforcer.
CVE-2021-30061 2 Belden, Schneider-electric 26 Eagle 20 Tofino 943 987-501-tx\/tx, Eagle 20 Tofino 943 987-501-tx\/tx Firmware, Eagle 20 Tofino 943 987-502 -tx\/mm and 23 more 2024-11-21 6.8 Medium
On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, physically proximate attackers can execute code via a crafted file on a USB stick.
CVE-2021-27734 1 Belden 2 Hirschmann Hios, Hisecos 2024-11-21 9.8 Critical
Hirschmann HiOS 07.1.01, 07.1.02, and 08.1.00 through 08.5.xx and HiSecOS 03.3.00 through 03.5.01 allow remote attackers to change the credentials of existing users.
CVE-2020-9307 1 Belden 1 Hirschmann Hios 2024-11-21 6.5 Medium
Hirschmann OS2, RSP, and RSPE devices before HiOS 08.3.00 allow a denial of service. An unauthenticated, adjacent attacker can cause an infinite loop on one of the HSR ring ports of the device. This effectively breaks the redundancy of the HSR ring. If the attacker can perform the same attack on a second device, the ring is broken into two parts (thus disrupting communication between devices in the different parts).
CVE-2020-6994 1 Belden 14 Hirschmann Eagle20, Hirschmann Eagle30, Hirschmann Embedded Ethernet Switch and 11 more 2024-11-21 9.8 Critical
A buffer overflow vulnerability was found in some devices of Hirschmann Automation and Control HiOS and HiSecOS. The vulnerability is due to improper parsing of URL arguments. An attacker could exploit this vulnerability by specially crafting HTTP requests to overflow an internal buffer. The following devices using HiOS Version 07.0.02 and lower are affected: RSP, RSPE, RSPS, RSPL, MSP, EES, EES, EESX, GRS, OS, RED. The following devices using HiSecOS Version 03.2.00 and lower are affected: EAGLE20/30.