Search Results (789 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2021-22769 1 Schneider-electric 2 Easergy T300, Easergy T300 Firmware 2026-06-29 5.3 Medium
A CWE-552: Files or Directories Accessible to External Parties vulnerability exists in Easergy T300 with firmware V2.7.1 and older that could expose files or directory content when access from an attacker is not restricted or incorrectly restricted.
CVE-2017-6034 1 Schneider-electric 2 Modbus, Modbus Firmware 2026-06-04 9.8 Critical
An authentication bypass by capture-replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download.
CVE-2018-7795 1 Schneider-electric 2 Powerlogic Pm5560, Powerlogic Pm5560 Firmware 2026-05-29 5.4 Medium
A Cross Protocol Injection vulnerability exists in Schneider Electric's PowerLogic (PM5560 prior to FW version 2.5.4) product. The vulnerability makes the product susceptible to cross site scripting attack on its web browser. User inputs can be manipulated to cause execution of java script code.
CVE-2017-7575 1 Schneider-electric 2 Modicon Tm221ce16r, Modicon Tm221ce16r Firmware 2026-05-29 9.8 Critical
Schneider Electric Modicon TM221CE16R 1.3.3.3 devices allow remote attackers to discover the application-protection password via a \x00\x01\x00\x00\x00\x05\x01\x5a\x00\x03\x00 request to the Modbus port (502/tcp). Subsequently the application may be arbitrarily downloaded, modified, and uploaded.
CVE-2023-6407 2 Microsoft, Schneider-electric 6 Windows 10 1507, Windows 11 21h2, Windows Server 2016 and 3 more 2026-02-25 5.3 Medium
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause arbitrary file deletion upon service restart when accessed by a local and low-privileged attacker.
CVE-2026-1227 1 Schneider-electric 2 Ecostruxure Building Operation Webstation, Ecostruxure Building Operation Workstation 2026-02-11 N/A
CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could cause unauthorized disclosure of local files, interaction within the EBO system, or denial of service conditions when a local user uploads a specially crafted TGML graphics file to the EBO server from Workstation.
CVE-2026-1226 1 Schneider-electric 2 Ecostruxure Building Operation Webstation, Ecostruxure Building Operation Workstation 2026-02-11 N/A
CWE‑94: Improper Control of Generation of Code vulnerability exists that could cause execution of untrusted or unintended code within the application when maliciously crafted design content is processed through a TGML graphics file.
CVE-2025-13905 1 Schneider-electric 2 Ecostruxure Process Expert, Ecostruxure Process Expert For Aveva System Platform 2026-01-30 N/A
CWE-276: Incorrect Default Permissions vulnerability exists that could cause privilege escalation through the reverse shell when one or more executable service binaries are modified in the installation folder by a local user with normal privilege upon service restart.
CVE-2025-13844 1 Schneider-electric 1 Ecostruxure Power Build - Rapsody 2026-01-16 N/A
CWE-415: Double Free vulnerability exists that could cause heap memory corruption when the end user imports a malicious project file (SSD file) shared by the attacker into Rapsody.
CVE-2025-13845 1 Schneider-electric 1 Ecostruxure Power Build - Rapsody 2026-01-16 N/A
CWE-416: Use After Free vulnerability that could cause remote code execution when the end user imports the malicious project file (SSD file) into Rapsody.
CVE-2018-1124 6 Canonical, Debian, Opensuse and 3 more 13 Ubuntu Linux, Debian Linux, Leap and 10 more 2025-12-18 7.8 High
procps-ng before version 3.3.15 is vulnerable to multiple integer overflows leading to a heap corruption in file2strvec function. This allows a privilege escalation for a local attacker who can create entries in procfs by starting processes, which could result in crashes or arbitrary code execution in proc utilities run by other users.
CVE-2018-1126 5 Canonical, Debian, Procps-ng Project and 2 more 13 Ubuntu Linux, Debian Linux, Procps-ng and 10 more 2025-12-17 N/A
procps-ng before version 3.3.15 is vulnerable to an incorrect integer size in proc/alloc.* leading to truncation/integer overflow issues. This flaw is related to CVE-2018-1124.
CVE-2025-11567 1 Schneider-electric 1 Powerchute Serial Shutdown 2025-11-14 N/A
CWE-276: Incorrect Default Permissions vulnerability exists that could cause elevated system access when the target installation folder is not properly secured.
CVE-2025-11566 1 Schneider-electric 1 Powerchute Serial Shutdown 2025-11-12 N/A
CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that would allow an attacker on the local network to gain access to the user account by performing an arbitrary number of authentication attempts with different credentials on the /REST/shutdownnow endpoint.
CVE-2025-11565 1 Schneider-electric 1 Powerchute Serial Shutdown 2025-11-12 N/A
CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause elevated system access when a Web Admin user on the local network tampers with the POST /REST/UpdateJRE request payload.
CVE-2014-5413 2 Aveva, Schneider-electric 2 Clearscada, Scada Expert Clearscada 2025-11-04 N/A
Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 uses the MD5 algorithm for an X.509 certificate, which makes it easier for remote attackers to spoof servers via a cryptographic attack against this algorithm.
CVE-2014-5412 2 Aveva, Schneider-electric 2 Clearscada, Scada Expert Clearscada 2025-11-04 N/A
Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 allows remote attackers to read database records by leveraging access to the guest account.
CVE-2014-5411 2 Aveva, Schneider-electric 2 Clearscada, Scada Expert Clearscada 2025-11-04 N/A
Multiple cross-site scripting (XSS) vulnerabilities in Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 allow remote authenticated users to inject arbitrary web script or HTML via unspecified vectors.
CVE-2025-7746 1 Schneider-electric 1 Altivar 2025-11-03 N/A
CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause an unvalidated data injected by a malicious user potentially leading to modify or read data in a victim’s browser.
CVE-2014-5407 1 Schneider-electric 1 Vampset 2025-11-03 N/A
Multiple stack-based buffer overflows in Schneider Electric VAMPSET 2.2.136 and earlier allow local users to cause a denial of service (application halt) via a malformed (1) setting file or (2) disturbance recording file.