| A Use of Hard-Coded Credentials issue was discovered in MRD-305-DIN versions older than 1.7.5.0, and MRD-315, MRD-355, MRD-455 versions older than 1.7.5.0. The device utilizes hard-coded credentials, which could allow for unauthorized local low-privileged access to the device. |
| A hard-coded password of tecn0visi0n for the dlxuser account in TecnoVISION DLX Spot Player4 (all known versions) allows remote attackers to log in via SSH and escalate privileges to root access with the same credentials. |
| Foscam networked devices use the same hardcoded SSL private key across different customers' installations, which allows remote attackers to defeat cryptographic protection mechanisms by leveraging knowledge of this key from another installation. |
| FusionSphere OpenStack V100R006C00 has an information exposure vulnerability. The software uses hard-coded cryptographic key to encrypt messages between certain components, which significantly increases the possibility that encrypted data may be recovered and results in information exposure. |
| The Integrated User Firewall (UserFW) feature was introduced in Junos OS version 12.1X47-D10 on the Juniper SRX Series devices to provide simple integration of user profiles on top of the existing firewall polices. As part of an internal security review of the UserFW services authentication API, hardcoded credentials were identified and removed which can impact both the SRX Series device, and potentially LDAP and Active Directory integrated points. An attacker may be able to completely compromise SRX Series devices, as well as Active Directory servers and services. When Active Directory is compromised, it may allow access to user credentials, workstations, servers performing other functions such as email, database, etc. Inter-Forest Active Directory deployments may also be at risk as the attacker may gain full administrative control over one or more Active Directories depending on the credentials supplied by the administrator of the AD domains and SRX devices performing integrated authentication of users, groups and devices. To identify if your device is potentially vulnerable to exploitation, check to see if the service is operating; from CLI review the following output: root@SRX-Firewall# run show services user-identification active-directory-access domain-controller status extensive A result of "Status: Connected" will indicate that the service is active on the device. To evaluate if user authentication is occurring through the device: root@SRX-Firewall# run show services user-identification active-directory-access active-directory-authentication-table all Next review the results to see if valid users and groups are returned. e.g. Domain: juniperlab.com Total entries: 3 Source IP Username groups state 172.16.26.1 administrator Valid 192.168.26.2 engg01 engineers Valid 192.168.26.3 guest01 guests Valid Domain: NULL Total entries: 8 Source IP Username groups state 192.168.26.4 Invalid 192.168.26.5 Invalid This will also indicate that Valid users and groups are authenticating through the device. Affected releases are Juniper Networks Junos OS 12.3X48 from 12.3X48-D30 and prior to 12.3X48-D35 on SRX series; 15.1X49 from 15.1X49-D40 and prior to 15.1X49-D50 on SRX series. Devices on any version of Junos OS 12.1X46, or 12.1X47 are unaffected by this issue. |
| WN-G300R3 firmware version 1.0.2 and earlier uses hardcoded credentials which may allow an attacker that can access the device to execute arbitrary code on the device. |
| WN-AX1167GR firmware version 3.00 and earlier uses hardcoded credentials which may allow an attacker that can access the device to execute arbitrary code on the device. |
| Trango Apex <= 2.1.1, ApexLynx < 2.0, ApexOrion < 2.0, ApexPlus <= 3.2.0, Giga <= 2.6.1, GigaLynx < 2.0, GigaOrion < 2.0, GigaPlus <= 3.2.3, GigaPro <= 1.4.1, StrataLink < 3.0, and StrataPro devices have a built-in, hidden root account, with a default password that was once stored in cleartext within a software update package on a Trango FTP server. This account is accessible via SSH and/or TELNET, and grants access to the underlying embedded UNIX OS on the device, allowing full control over it. |
| Trango ApexLynx 2.0, ApexOrion 2.0, GigaLynx 2.0, GigaOrion 2.0, and StrataLink 3.0 devices have a built-in, hidden root account, with a default password for which the MD5 hash value is public (but the cleartext value is perhaps not yet public). This account is accessible via SSH and/or TELNET, and grants access to the underlying embedded UNIX OS on the device, allowing full control over it. |
| MaLion for Windows and Mac versions 3.2.1 to 5.2.1 uses a hardcoded cryptographic key which may allow an attacker to alter the connection settings of Terminal Agent and spoof the Relay Service. |
| A vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which the web service contains a hidden system account with a hardcoded password. An attacker can use this information to log into the system with high-privilege credentials. |
| Green Packet DX-350 Firmware version v2.8.9.5-g1.4.8-atheeb has a default password of admin for the admin account. |
| On the TP-Link TL-SG108E 1.0, there is a hard-coded ciphering key (a long string beginning with Ei2HNryt). This affects the 1.1.2 Build 20141017 Rel.50749 firmware. |
| EMC ViPR SRM, EMC Storage M&R, EMC VNX M&R, EMC M&R for SAS Solution Packs (EMC ViPR SRM prior to 4.1, EMC Storage M&R prior to 4.1, EMC VNX M&R all versions, EMC M&R (Watch4Net) for SAS Solution Packs all versions) contain undocumented accounts with default passwords for Webservice Gateway and RMI JMX components. A remote attacker with the knowledge of the default password may potentially use these accounts to run arbitrary web service and remote procedure calls on the affected system. |
| DragonWave Horizon 1.01.03 wireless radios have hardcoded login credentials (such as the username of energetic and password of wireless) meant to allow the vendor to access the devices. These credentials can be used in the web interface or by connecting to the device via TELNET. This is fixed in recent versions including 1.4.8. |
| Schneider Electric SoMachine Basic 1.4 SP1 and Schneider Electric Modicon TM221CE16R 1.3.3.3 devices have a hardcoded-key vulnerability. The Project Protection feature is used to prevent unauthorized users from opening an XML protected project file, by prompting the user for a password. This XML file is AES-CBC encrypted; however, the key used for encryption (SoMachineBasicSoMachineBasicSoMa) cannot be changed. After decrypting the XML file with this key, the user password can be found in the decrypted data. After reading the user password, the project can be opened and modified with the Schneider product. |
| Trango Altum AC600 devices have a built-in, hidden root account, with a default password of abcd1234. This account is accessible via SSH and/or TELNET, and grants access to the underlying embedded UNIX OS on the device, allowing full control over it. |
| In some circumstances, an F5 BIG-IP version 12.0.0 to 12.1.2 and 13.0.0 Azure cloud instance may contain a default administrative password which could be used to remotely log into the BIG-IP system. The impacted administrative account is the Azure instance administrative user that was created at deployment. The root and admin accounts are not vulnerable. An attacker may be able to remotely access the BIG-IP host via SSH. |
| D-Link DGS-1100 devices with Rev.B firmware 1.01.018 have a hardcoded SSL private key, which allows man-in-the-middle attackers to spoof devices by hijacking an HTTPS session. |
| D-Link DVG-N5402SP with firmware W1000CN-00, W1000CN-03, or W2000EN-00 has a default password of root for the root account and tw for the tw account, which makes it easier for remote attackers to obtain administrative access. |