| ACTi cameras including the D, B, I, and E series using firmware version A1D-500-V6.11.31-AC fail to properly restrict access to the factory reset page. An unauthenticated, remote attacker can exploit this vulnerability by directly accessing the http://x.x.x.x/setup/setup_maintain_firmware-default.html page. This will allow an attacker to perform a factory reset on the device, leading to a denial of service condition or the ability to make use of default credentials (CVE-2017-3186). |
| iball Baton 150M iB-WRA150N v1 00000001 1.2.6 build 110401 Rel.47776n devices are prone to an authentication bypass vulnerability that allows remote attackers to view and modify administrative router settings by reading the HTML source code of the password.cgi file. |
| An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Users do not have any option to change their own passwords. |
| An issue was discovered in Siemens SICAM PAS before 8.00. A factory account with hard-coded passwords is present in the SICAM PAS installations. Attackers might gain privileged access to the database over Port 2638/TCP. |
| MEDHOST Connex contains hard-coded credentials that are used for customer database access. An attacker with knowledge of the hard-coded credentials and the ability to communicate directly with the database may be able to obtain or modify sensitive patient and financial information. Connex utilizes an IBM i DB2 user account for database access. The account name is HMSCXPDN. Its password is hard-coded in multiple places in the application. Customers do not have the option to change this password. The account has elevated DB2 roles, and can access all objects or database tables on the customer DB2 database. This account can access data through ODBC, FTP, and TELNET. Customers without Connex installed are still vulnerable because the MEDHOST setup program creates this account. |
| Gynoii has a password of guest for the backdoor guest account and a password of 12345 for the backdoor admin account. |
| iBaby M3S has a password of admin for the backdoor admin account. |
| A vulnerability in Cisco Umbrella Insights Virtual Appliances 2.1.0 and earlier could allow an authenticated, local attacker to log in to an affected virtual appliance with root privileges. The vulnerability is due to the presence of default, static user credentials for an affected virtual appliance. An attacker could exploit this vulnerability by using the hypervisor console to connect locally to an affected system and then using the static credentials to log in to an affected virtual appliance. A successful exploit could allow the attacker to log in to the affected appliance with root privileges. Cisco Bug IDs: CSCvg31220. |
| EMC ESRS Policy Manager prior to 6.8 contains an undocumented account (OpenDS admin) with a default password. A remote attacker with the knowledge of the default password may login to the system and gain administrator privileges to the local LDAP directory server. |
| Schneider Electric SoMachine Basic 1.4 SP1 and Schneider Electric Modicon TM221CE16R 1.3.3.3 devices have a hardcoded-key vulnerability. The Project Protection feature is used to prevent unauthorized users from opening an XML protected project file, by prompting the user for a password. This XML file is AES-CBC encrypted; however, the key used for encryption (SoMachineBasicSoMachineBasicSoMa) cannot be changed. After decrypting the XML file with this key, the user password can be found in the decrypted data. After reading the user password, the project can be opened and modified with the Schneider product. |
| The AT&T U-verse 9.2.2h0d83 firmware for the Arris NVG589 and NVG599 devices, when IP Passthrough mode is not used, configures ssh-permanent-enable WAN SSH logins to the remotessh account with the 5SaP9I26 password, which allows remote attackers to access a "Terminal shell v1.0" service, and subsequently obtain unrestricted root privileges, by establishing an SSH session and then entering certain shell metacharacters and BusyBox commands. |
| The SMI-S service in Dell Storage Manager versions earlier than 16.3.20 (aka 2016 R3.20) is protected using a hard-coded password. A remote user with the knowledge of the password might potentially disable the SMI-S service via HTTP requests, affecting storage management and monitoring functionality via the SMI-S interface. This issue, aka DSM-30415, only affects a Windows installation of the Data Collector (not applicable to the virtual appliance). |
| The Fedora Nagios package uses "nagiosadmin" as the default password for the "nagiosadmin" administrator account, which makes it easier for remote attackers to obtain access by leveraging knowledge of the credentials. |
| Mutiny 7.2.0-10788 suffers from Hardcoded root password. |
| Common encryption key appears to be used across all deployed instances of Serv-U FTP Server. Because of this an encrypted value that is exposed to an attacker can be simply recovered to plaintext. |
| Ovarro TBox TWinSoft uses the custom hardcoded user “TWinSoft” with a hardcoded key. |
| Nokia Fastmile 3tg00118abad52 devices shipped by Optus are shipped with a default hardcoded admin account of admin:Nq+L5st7o This account can be used locally to access the web admin interface. |
| GE UR bootloader binary Version 7.00, 7.01 and 7.02 included unused hardcoded credentials. Additionally, a user with physical access to the UR IED can interrupt the boot sequence by rebooting the UR. |
| An attacker can gain VxWorks Shell after login due to hard-coded credentials on a KUKA KR C4 control software for versions prior to 8.7 or any product running KSS. |
| An issue was discovered in Elspec G5 digital fault recorder versions 1.1.4.15 and before. A hardcoded backdoor session ID exists that can be used for further access to the device, including reconfiguration tasks. |