| CVE-2025-62307 | 1 Hcl Software | 1 Iem | 2026-08-21 | 5.4 Medium |
| HCL IntelliOps Event Management (IEM) is affected by insufficient logging. Insufficient logging weakens accountability, obscures attack detection, and enables privilege probing. | ||||
| CVE-2025-62306 | 1 Hcl Software | 1 Iem | 2026-08-21 | 5 Medium |
| HCL IntelliOps Event Management (IEM) is affected by information omission. The lack of information breaks auditability and observability of a workflow. if an attacker were to gain access to the application, the insufficient logging could hinder incident response. | ||||
| CVE-2025-62300 | 1 Hcl Software | 1 Iem | 2026-08-21 | 5.9 Medium |
| HCL IntelliOps Event Management (IEM) is affected by a race condition. A "timing window" can occur where an attacker can modify the resource causing unpredictable behavior. | ||||
| CVE-2025-62299 | 1 Hcl Software | 1 Iem | 2026-08-21 | 6.6 Medium |
| HCL IntelliOps Event Management (IEM) is affected by a least privileges violation which could allow an attacker to access the resource with the elevated privilege that could not be accessed with the attacker's original privileges. | ||||
| CVE-2026-21784 | 1 Hcl Software | 1 Iem | 2026-08-21 | 4.8 Medium |
| HCL IntelliOps Event Management (IEM) is affected by missing or insecure Cross-Origin Security headers. This issue makes the application's environment and resources susceptible to unauthorized external interaction and potential exploitation. | ||||
| CVE-2024-23580 | 1 Hcl Software | 1 Dryice Optibot Reset Station | 2025-07-12 | 6.5 Medium |
| HCL DRYiCE Optibot Reset Station is impacted by insecure encryption of One-Time Passwords (OTPs). This could allow an attacker with access to the database to recover some or all encrypted values. | ||||
| CVE-2024-23579 | 1 Hcl Software | 1 Dryice Optibot Reset Station | 2025-07-12 | 6.5 Medium |
| HCL DRYiCE Optibot Reset Station is impacted by insecure encryption of security questions. This could allow an attacker with access to the database to recover some or all encrypted values. | ||||
| CVE-2024-30120 | 1 Hcl Software | 1 Dryice Optibot Reset Station | 2024-11-21 | 2.9 Low |
| HCL DRYiCE Optibot Reset Station is impacted by an Unused Parameter in the web application. | ||||
| CVE-2024-30119 | 1 Hcl Software | 1 Dryice Optibot Reset Station | 2024-11-21 | 3.7 Low |
| HCL DRYiCE Optibot Reset Station is impacted by a missing Strict Transport Security Header. This could allow an attacker to intercept or manipulate data during redirection. | ||||