Search Results (21 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2026-33920 1 Nozomi Networks 2 Cmc, Guardian 2026-09-08 3.5 Low
A cross-site request forgery vulnerability was discovered in the login functionality (both standard and SAML) due to missing validation of the anti-CSRF token. An attacker with a valid account can trick a victim into unknowingly authenticating with the attacker's credentials. Any operation performed by the victim in this state is attributed to the attacker's account, compromising the integrity of the audit trail.
CVE-2026-33391 1 Nozomi Networks 2 Cmc, Guardian 2026-09-08 5.4 Medium
An access control vulnerability was discovered in the Smart Polling configuration functionality due to insufficient validation of user privileges. An authenticated user with limited privileges can remotely bypass the intended access control of the web management interface and modify the Smart Polling discovery configuration. This allows the attacker to disrupt the visibility of assets in the monitored network.
CVE-2026-33389 1 Nozomi Networks 3 Arc, Cmc, Guardian 2026-09-08 7.5 High
An improper certificate/host key validation vulnerability was discovered in the Smart Polling functionality, which established encrypted connections to target devices without validating the remote host's identity, and no option was provided to enable it. A man-in-the-middle attacker positioned between a sensor and a polled device can, during a polling session, impersonate the device and intercept the communication, including the credentials used to access it. The captured credentials can then be replayed to authenticate against the device itself or against other devices sharing the same credentials, allowing the attacker to access and tamper with the device's data and to disrupt its operations.
CVE-2026-33388 1 Nozomi Networks 2 Cmc, Guardian 2026-09-08 7.4 High
An access control vulnerability was discovered in the Credentials Manager functionality due to insufficient validation of user privileges. A remote authenticated user with limited privileges can view a limited subset of the available entries in the Credentials Manager. The actual credential values are not directly visible, but the user can delete entries or edit their properties. An attacker who deletes or edits an entry can disrupt authentication for dependent devices, and one who manipulates an entry's configuration may be able to indirectly obtain the credentials.
CVE-2026-33387 1 Nozomi Networks 2 Cmc, Guardian 2026-09-08 4.6 Medium
A template injection vulnerability was discovered in the Dashboards functionality due to improper validation of an input parameter. An authenticated user with the required privileges can define a dashboard containing a malicious payload, or a victim can be socially engineered into importing a malicious dashboard. When the victim views or imports the dashboard, the payload executes in their browser context, allowing the attacker to modify application data or disrupt application availability.
CVE-2026-33922 1 Nozomi Networks 1 Arc 2026-08-11 6 Medium
A path traversal vulnerability was discovered in the Offline archives functionality of the local web interface due to insufficient validation of an input parameter. A local user with administrative credentials for the web interface could submit an archive name containing traversal sequences and delete arbitrary files reachable by the Arc process, which runs with administrative privileges on the host.
CVE-2026-33921 1 Nozomi Networks 1 Arc 2026-08-11 5.2 Medium
The Windows installer deployed Npcap leaving its access restriction option at the insecure default value, so the driver was accessible to every local user of the host instead of being restricted to administrators only. A local user without administrative privileges could use the Npcap driver to capture the traffic reaching the host, which discloses information belonging both to the host and to other systems on the same network segment, and to send arbitrary raw packets on that segment.
CVE-2026-33390 2 Nozomi Networks, Nozominetworks 4 Cmc, Guardian, Cmc and 1 more 2026-08-11 8.1 High
An Incorrect Privilege Assignment vulnerability was discovered in the synchronization functionality due to Arc sensors receiving CLI permissions. An authenticated user with limited privileges can push administrative CLI commands through the sync, altering the device configuration, and/or affecting its availability.
CVE-2026-31984 2 Nozomi Networks, Nozominetworks 4 Cmc, Guardian, Cmc and 1 more 2026-08-11 7.5 High
A denial-of-service vulnerability caused by unbounded resource allocation was discovered in the audit logging functionality, due to a missing size limit on input recorded into audit entries. An unauthenticated attacker can submit requests containing excessively large input that is recorded into audit entries, possibly exhausting the available disk space and rendering the system inoperable.
CVE-2026-31983 2 Nozomi Networks, Nozominetworks 4 Cmc, Guardian, Cmc and 1 more 2026-08-11 5.3 Medium
A Missing Authentication vulnerability was discovered in the SSH keys synchronization endpoint. An unauthenticated attacker can send a request to the SSH keys synchronization endpoint and obtain the list of users that have uploaded their public SSH keys, their groups, and the uploaded public SSH keys.
CVE-2026-31982 2 Nozomi Networks, Nozominetworks 4 Cmc, Guardian, Cmc and 1 more 2026-08-11 7.1 High
An Open Redirect vulnerability was discovered in the SAML Single Sign-On functionality due to insufficient validation of a user-controlled redirection parameter. An unauthenticated attacker can craft a request to the SAML sign-in endpoint and poison the cached SAML redirection for other users who subsequently initiate SAML Single Sign-On, enabling phishing and credential-theft attacks, as well as disrupting SAML authentication for all affected users.
CVE-2026-31981 2 Nozomi Networks, Nozominetworks 4 Cmc, Guardian, Cmc and 1 more 2026-08-11 5.9 Medium
A Stored HTML Injection vulnerability was discovered in the Diagram tab and Graph view due to a shared input validation function being insufficiently restrictive. An authenticated user with administrative privileges can inject malicious HTML tags into N2OS configuration data through multiple input vectors. When a victim views the affected data in the Diagram tab and Graph view, the injected HTML renders in their browser, enabling phishing and possibly open redirect attacks. Full XSS exploitation and direct information disclosure are prevented by the existing input validation and Content Security Policy configuration.
CVE-2026-31985 1 Nozomi Networks 1 Remote Collector 2026-07-10 8.1 High
When the upstream Guardian or CMC was configured in the Remote Collector via n2os-tui, the generated configuration disabled TLS certificate verification, and no option was provided to enable it. A malicious actor could perform a man-in-the-middle attack and intercept the communication between the Remote Collector and the Guardian or CMC. This could result in theft of the sync token, impersonation of the server, injection of spoofed data (such as false asset information or vulnerabilities) into the Guardian or CMC, or disruption of the data flow between the Remote Collector and the Guardian or CMC.
CVE-2025-40892 2 Nozomi Networks, Nozominetworks 4 Cmc, Guardian, Cmc and 1 more 2026-04-20 8.9 High
A Stored Cross-Site Scripting vulnerability was discovered in the Reports functionality due to improper validation of an input parameter. An authenticated user with report privileges can define a malicious report containing a JavaScript payload, or a victim can be socially engineered to import a malicious report template. When the victim views or imports the report, the XSS executes in their browser context, allowing the attacker to perform unauthorized actions as the victim, such as modify application data, disrupt application availability, and access limited sensitive information.
CVE-2025-40891 2 Nozomi Networks, Nozominetworks 4 Cmc, Guardian, Cmc and 1 more 2026-04-20 4.7 Medium
A Stored HTML Injection vulnerability was discovered in the Time Machine Snapshot Diff functionality due to improper validation of network traffic data. An unauthenticated attacker can send specially crafted network packets at two different times to inject HTML tags into asset attributes across two snapshots. Exploitation requires a victim to use the Time Machine Snapshot Diff feature on those specific snapshots and perform specific GUI actions, at which point the injected HTML renders in their browser, enabling phishing and open redirect attacks. Full XSS exploitation is prevented by input validation and Content Security Policy. Attack complexity is high due to multiple required conditions.
CVE-2025-40893 2 Nozomi Networks, Nozominetworks 4 Cmc, Guardian, Cmc and 1 more 2026-04-20 6.1 Medium
A Stored HTML Injection vulnerability was discovered in the Asset List functionality due to improper validation of network traffic data. An unauthenticated attacker can send specially crafted network packets to inject HTML tags into asset attributes. When a victim views the affected assets in the Asset List (and similar functions), the injected HTML renders in their browser, enabling phishing and possibly open redirect attacks. Full XSS exploitation and direct information disclosure are prevented by the existing input validation and Content Security Policy configuration.
CVE-2025-40898 2 Nozomi Networks, Nozominetworks 4 Cmc, Guardian, Cmc and 1 more 2026-04-20 8.1 High
A path traversal vulnerability was discovered in the Import Arc data archive functionality due to insufficient validation of the input file. An authenticated user with limited privileges, by uploading a specifically-crafted Arc data archive, can potentially write arbitrary files in arbitrary paths, altering the device configuration and/or affecting its availability.
CVE-2025-40894 2 Nozomi Networks, Nozominetworks 4 Cmc, Guardian, Cmc and 1 more 2026-04-20 4.4 Medium
A Stored HTML Injection vulnerability was discovered in the Alerted Nodes Dashboard functionality due to improper validation on an input parameter. A malicious authenticated user with the required privileges could edit a node label to inject HTML tags. If the system is configured to use the Alerted Nodes Dashboard, and alerts are reported for the affected node, then the injected HTML may render in the browser of a victim user interacting with it, enabling phishing and possibly open redirect attacks. Full XSS exploitation and direct information disclosure are prevented by the existing input validation and Content Security Policy configuration.
CVE-2025-40890 1 Nozomi Networks 2 Cmc, Guardian 2026-04-15 7.9 High
A Stored Cross-Site Scripting vulnerability was discovered in the Dashboards functionality due to improper validation of an input parameter. An authenticated low-privilege user can craft a malicious dashboard containing a JavaScript payload and share it with victim users, or a victim can be socially engineered to import a malicious dashboard template. When the victim views or imports the dashboard, the XSS executes in their browser context, allowing the attacker to perform unauthorized actions as the victim, such as modify application data, disrupt application availability, and access limited sensitive information.
CVE-2025-40895 2 Nozomi Networks, Nozominetworks 2 Cmc, Cmc 2026-03-05 4.8 Medium
A Stored HTML Injection vulnerability was discovered in the CMC's Sensor Map functionality due to improper validation on connected Guardians' properties. A malicious authenticated user with administrator privileges on a Guardian connected to a CMC can edit the Guardian's properties to inject HTML tags. If the Sensor Map functionality is enabled in the CMC, when a victim CMC user interacts with it, then the injected HTML may render in their browser, enabling phishing and possibly open redirect attacks. Full XSS exploitation and direct information disclosure are prevented by the existing input validation and Content Security Policy configuration.