In the Linux kernel, the following vulnerability has been resolved:
iommu/amd: Fix ineffective error check in nested domain allocation
amd_iommu_pdom_id_alloc() returns an int: a domain ID on success, or the
negative errno from ida_alloc_range() when the ID space is exhausted or
memory is short. amd_iommu_alloc_domain_nested() stores that return value
in gdom_info->hdom_id, which is a u32, and only then tests it:
gdom_info->hdom_id = amd_iommu_pdom_id_alloc();
if (gdom_info->hdom_id <= 0) {
The assignment discards the sign, so -ENOSPC becomes 0xffffffe4 and the
test never fires. The nested domain is then set up with a host domain ID
that was never allocated, instead of the allocation failing with -ENOSPC.
Keep the value in an int, test it there, and store it only once it is
known to be valid, which is what the other amd_iommu_pdom_id_alloc()
callers already do.
iommu/amd: Fix ineffective error check in nested domain allocation
amd_iommu_pdom_id_alloc() returns an int: a domain ID on success, or the
negative errno from ida_alloc_range() when the ID space is exhausted or
memory is short. amd_iommu_alloc_domain_nested() stores that return value
in gdom_info->hdom_id, which is a u32, and only then tests it:
gdom_info->hdom_id = amd_iommu_pdom_id_alloc();
if (gdom_info->hdom_id <= 0) {
The assignment discards the sign, so -ENOSPC becomes 0xffffffe4 and the
test never fires. The nested domain is then set up with a host domain ID
that was never allocated, instead of the allocation failing with -ENOSPC.
Keep the value in an int, test it there, and store it only once it is
known to be valid, which is what the other amd_iommu_pdom_id_alloc()
callers already do.
Metrics
Affected Vendors & Products
Advisories
No advisories yet.
Fixes
Solution
No solution given by the vendor.
Workaround
No workaround given by the vendor.
References
History
Fri, 25 Sep 2026 15:45:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| Weaknesses | CWE-190 CWE-680 |
Fri, 25 Sep 2026 15:00:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| Metrics |
cvssV3_1
|
Fri, 25 Sep 2026 10:30:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| Description | In the Linux kernel, the following vulnerability has been resolved: iommu/amd: Fix ineffective error check in nested domain allocation amd_iommu_pdom_id_alloc() returns an int: a domain ID on success, or the negative errno from ida_alloc_range() when the ID space is exhausted or memory is short. amd_iommu_alloc_domain_nested() stores that return value in gdom_info->hdom_id, which is a u32, and only then tests it: gdom_info->hdom_id = amd_iommu_pdom_id_alloc(); if (gdom_info->hdom_id <= 0) { The assignment discards the sign, so -ENOSPC becomes 0xffffffe4 and the test never fires. The nested domain is then set up with a host domain ID that was never allocated, instead of the allocation failing with -ENOSPC. Keep the value in an int, test it there, and store it only once it is known to be valid, which is what the other amd_iommu_pdom_id_alloc() callers already do. | |
| Title | iommu/amd: Fix ineffective error check in nested domain allocation | |
| First Time appeared |
Linux
Linux linux Kernel |
|
| CPEs | cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:* | |
| Vendors & Products |
Linux
Linux linux Kernel |
|
| References |
|
Projects
Sign in to view the affected projects.
Status: PUBLISHED
Assigner: Linux
Published:
Updated: 2026-09-25T14:41:49.625Z
Reserved: 2026-09-25T10:19:56.068Z
Link: CVE-2026-98002
No data.
Status : Received
Published: 2026-09-25T11:17:28.430
Modified: 2026-09-25T15:18:03.580
Link: CVE-2026-98002
No data.
OpenCVE Enrichment
Updated: 2026-09-25T15:30:06Z