In the Linux kernel, the following vulnerability has been resolved:

iommu/amd: Fix ineffective error check in nested domain allocation

amd_iommu_pdom_id_alloc() returns an int: a domain ID on success, or the
negative errno from ida_alloc_range() when the ID space is exhausted or
memory is short. amd_iommu_alloc_domain_nested() stores that return value
in gdom_info->hdom_id, which is a u32, and only then tests it:

gdom_info->hdom_id = amd_iommu_pdom_id_alloc();
if (gdom_info->hdom_id <= 0) {

The assignment discards the sign, so -ENOSPC becomes 0xffffffe4 and the
test never fires. The nested domain is then set up with a host domain ID
that was never allocated, instead of the allocation failing with -ENOSPC.

Keep the value in an int, test it there, and store it only once it is
known to be valid, which is what the other amd_iommu_pdom_id_alloc()
callers already do.
Advisories

No advisories yet.

Fixes

Solution

No solution given by the vendor.


Workaround

No workaround given by the vendor.

History

Fri, 25 Sep 2026 15:45:00 +0000

Type Values Removed Values Added
Weaknesses CWE-190
CWE-680

Fri, 25 Sep 2026 15:00:00 +0000

Type Values Removed Values Added
Metrics cvssV3_1

{'score': 7.8, 'vector': 'CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H'}


Fri, 25 Sep 2026 10:30:00 +0000

Type Values Removed Values Added
Description In the Linux kernel, the following vulnerability has been resolved: iommu/amd: Fix ineffective error check in nested domain allocation amd_iommu_pdom_id_alloc() returns an int: a domain ID on success, or the negative errno from ida_alloc_range() when the ID space is exhausted or memory is short. amd_iommu_alloc_domain_nested() stores that return value in gdom_info->hdom_id, which is a u32, and only then tests it: gdom_info->hdom_id = amd_iommu_pdom_id_alloc(); if (gdom_info->hdom_id <= 0) { The assignment discards the sign, so -ENOSPC becomes 0xffffffe4 and the test never fires. The nested domain is then set up with a host domain ID that was never allocated, instead of the allocation failing with -ENOSPC. Keep the value in an int, test it there, and store it only once it is known to be valid, which is what the other amd_iommu_pdom_id_alloc() callers already do.
Title iommu/amd: Fix ineffective error check in nested domain allocation
First Time appeared Linux
Linux linux Kernel
CPEs cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*
Vendors & Products Linux
Linux linux Kernel
References

Projects

Sign in to view the affected projects.

cve-icon MITRE

Status: PUBLISHED

Assigner: Linux

Published:

Updated: 2026-09-25T14:41:49.625Z

Reserved: 2026-09-25T10:19:56.068Z

Link: CVE-2026-98002

cve-icon Vulnrichment

No data.

cve-icon NVD

Status : Received

Published: 2026-09-25T11:17:28.430

Modified: 2026-09-25T15:18:03.580

Link: CVE-2026-98002

cve-icon Redhat

No data.

cve-icon OpenCVE Enrichment

Updated: 2026-09-25T15:30:06Z

Weaknesses