| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Shotwell version 0.24.4 or earlier and 0.25.3 or earlier is vulnerable to an information disclosure in the web publishing plugins resulting in potential password and oauth token plaintext transmission |
| The Vibease Wireless Remote Vibrator app for Android and the Vibease Chat app for iOS use cleartext to exchange messages with other apps and the PLAIN SASL mechanism to send auth tokens to Vibease servers, which allows remote attackers to obtain user credentials, messages, and other sensitive information by sniffing the network for XMPP traffic. |
| An issue was discovered in certain Apple products. iOS before 10.3 is affected. The issue involves the "iTunes Store" component. It allows man-in-the-middle attackers to modify the client-server data stream to iTunes sandbox web services by leveraging use of cleartext HTTP. |
| An unintended cleartext issue exists in Go before 1.8.4 and 1.9.x before 1.9.1. RFC 4954 requires that, during SMTP, the PLAIN auth scheme must only be used on network connections secured with TLS. The original implementation of smtp.PlainAuth in Go 1.0 enforced this requirement, and it was documented to do so. In 2013, upstream issue #5184, this was changed so that the server may decide whether PLAIN is acceptable. The result is that if you set up a man-in-the-middle SMTP server that doesn't advertise STARTTLS and does advertise that PLAIN auth is OK, the smtp.PlainAuth implementation sends the username and password. |
| IBM Tivoli Monitoring Portal V6 client could allow a local attacker to gain elevated privileges for IBM Tivoli Monitoring, caused by the default console connection not being encrypted. IBM X-Force ID: 123487. |
| IBM Tivoli Endpoint Manager (IBM BigFix Platform 9.2 and 9.5) transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors. IBM X-Force ID: 123911. |
| Heimdal before 7.4 allows remote attackers to impersonate services with Orpheus' Lyre attacks because it obtains service-principal names in a way that violates the Kerberos 5 protocol specification. In _krb5_extract_ticket() the KDC-REP service name must be obtained from the encrypted version stored in 'enc_part' instead of the unencrypted version stored in 'ticket'. Use of the unencrypted version provides an opportunity for successful server impersonation and other attacks. NOTE: this CVE is only for Heimdal and other products that embed Heimdal code; it does not apply to other instances in which this part of the Kerberos 5 protocol specification is violated. |
| Vulnerability in the MySQL Server component of Oracle MySQL (subcomponent: Server: C API). Supported versions that are affected are 5.5.55 and earlier and 5.6.35 and earlier. Difficult to exploit vulnerability allows low privileged attacker with network access via multiple protocols to compromise MySQL Server. Successful attacks of this vulnerability can result in unauthorized access to critical data or complete access to all MySQL Server accessible data. CVSS 3.0 Base Score 5.3 (Confidentiality impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N). NOTE: the previous information is from the April 2017 CPU. Oracle has not commented on third-party claims that this issue allows man-in-the-middle attackers to hijack the authentication of users by leveraging incorrect ordering of security parameter verification in a client, aka, "The Riddle". |
| Incorrect access control in TP-Link Tapo before v3.1.315 allows attackers to access user credentials in plaintext. |
| An issue was discovered in Sesami Cash Point & Transport Optimizer (CPTO) version 6.3.8.6 (#718), allows remote attackers to obtain sensitive information via transmission of unencrypted, cleartext credentials during Password Reset feature. |
|
IBM Spectrum Protect Plus 10.1.0 through 10.1.12 discloses sensitive information due to unencrypted data being used in the communication flow between Spectrum Protect Plus vSnap and its agents. An attacker could obtain information using main in the middle techniques. IBM X-Force ID: 182106.
|
| Insights for Vulnerability Remediation (IVR) is vulnerable to man-in-the-middle attacks that may lead to information disclosure. This requires privileged network access.
|
| The affected product is vulnerable due to cleartext transmission of credentials seen in the CIMPLICITY network, which can be easily spoofed and used to log in to make operational changes to the system. |
| ISaGRAF Workbench communicates with Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x using TCP/IP. This communication protocol provides various file system operations, as well as the uploading of applications. Data is transferred over this protocol unencrypted, which could allow a remote unauthenticated attacker to upload, read, and delete files. |
| LRM version 2.4 and lower does not implement TLS encryption. A malicious actor can MITM attack sensitive data in-transit, including credentials. |
| AutomationDirect DirectLOGIC is vulnerable to a specifically crafted serial message to the CPU serial port that will cause the PLC to respond with the PLC password in cleartext. This could allow an attacker to access and make unauthorized changes. This issue affects: AutomationDirect DirectLOGIC D0-06 series CPUs D0-06DD1 versions prior to 2.72; D0-06DD2 versions prior to 2.72; D0-06DR versions prior to 2.72; D0-06DA versions prior to 2.72; D0-06AR versions prior to 2.72; D0-06AA versions prior to 2.72; D0-06DD1-D versions prior to 2.72; D0-06DD2-D versions prior to 2.72; D0-06DR-D versions prior to 2.72; |
| Any attempt (good or bad) to log into AutomationDirect Stride Field I/O with a web browser may result in the device responding with its password in the communication packets. |
| Fresenius Kabi Agilia Link + version 3.0 does not enforce transport layer encryption. Therefore, transmitted data may be sent in cleartext. Transport layer encryption is offered on Port TCP/443, but the affected service does not perform an automated redirect from the unencrypted service on Port TCP/80 to the encrypted service. |
| GE UR firmware versions prior to version 8.1x web server interface is supported on UR over HTTP protocol. It allows sensitive information exposure without authentication. |
| Delta Electronics DIAEnergie (Version 1.7.5 and prior) is vulnerable to cleartext transmission as the web application runs by default on HTTP. This could allow an attacker to remotely read transmitted information between the client and product. |